Brand: sytt
Material: Cold rolled coil; SUS 304, 316.
Width: 320mm, 380mm, 460mm; 480mm, 520mm, 535mm.
Pitch: 40/45/50mm.
Center Distance: 500-4000mm.
Header Pipe: 89mm, 114mm. (3B, 4B)
Radiator Standard: JB 5347-2013, BS EN 50216-6-2002
Hot-dip-galvanizing Standard: GB-T 13912, ISO 1461, JIS H 8641, ASTM A123, NZS-4680
To ensure that a transformer HDG (Hot-Dip Galvanized) radiator does not leak, you can follow these steps:
1. Proper Installation: Ensure that the radiator is installed correctly following the manufacturer's guidelines. This includes securely attaching the radiator to the transformer tank using appropriate fasteners and gaskets.
2. Regular Inspection: Regularly inspect the radiator for any signs of leakage. Look for any visible cracks, holes, or corrosion on the surface of the radiator. Also, check the gaskets and seals for any signs of wear or damage.
3. Maintain Proper Water Levels: The Transformer Radiator uses water to cool down the transformer. Maintain the proper water level in the radiator to prevent overheating and potential leaks. Regularly check and refill the water if needed, following the transformer manufacturer's instructions.
4. Prevent Corrosion: HDG Radiator is galvanized to provide corrosion resistance. However, over time, the galvanized coating may wear off. To prevent corrosion, regularly inspect the radiator and touch up any areas where the galvanized coating has worn off using appropriate zinc-rich paint or coating.
5. Control Water Quality: Poor water quality can lead to corrosion and leaks in the radiator. Ensure that the water used in the radiator is clean and free from impurities. Use water treatment methods such as filtration, deionization, or chemical treatment to maintain the water quality within the recommended limits.
6. Regular Maintenance: Schedule regular maintenance checks for the transformer and radiator. This includes cleaning the radiator surface, checking the gaskets and seals, inspecting the fasteners, and ensuring proper functioning of the cooling system.
7. Promptly Address Issues: If any leakage or damage is detected during inspection, take immediate action to rectify the problem. This may involve repairing or replacing the damaged radiator or gaskets.
By following these steps, you can help ensure that your transformer Hot-Dip Galvanizing Radiator remains leak-free and functions efficiently.
Packaging: pallet
Productivity: 20,000 tons/year
Transportation: Ocean,Land,Air,Express,Express
Place of Origin: China
Supply Ability: 800 tons/month
Certificate: ISO9001,14001,45001,3834
HS Code: 85049019
Port: Dalian,Yingkou,Manzhouli
Payment Type: L/C,T/T
Incoterm: FOB
GET IN TOUCH
If you have any questions our products or services,feel free to reach out to us.Provide unique experiences for everyone involved with a brand.we’ve got preferential price and best-quality products for you.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.